Biolight Patient Monitor 12.1′” Touch Screen – Mainstream

SKU: VPMB121M

Monitor all vital parameters, including mainstream ETCO₂, on a clear 12.1-inch display. Designed for versatility with wall or trolley mounting, and supplied with essential accessories such as BP cuffs, ECG leads, and SpO₂ sensors.

  • Features
  • Specifications
  • Resources

• Comprehensive monitoring of all vital parameters
• 12.1” high-resolution TFT LCD touchscreen
• Integrated rear accessory compartment for storing monitoring equipment
• Intuitive interface with customisable display layouts via swipe gestures
• Automatic brightness adjustment based on ambient light
• Wired and wireless network connectivity options
• Standard EtCO₂ monitoring – available in mainstream
• Wall or trolley mount options available

Power Supply Input voltage: AC (100-240) V (±10%); Frequency: 50Hz/60Hz; Input power: 100VA
Battery Type: Rechargeable li-ion battery, 11.1V 2.5Ah/5.0Ah; Operating time: >240 minutes (2.5Ah)(1 new and fully charged battery at 25°C temperature, connecting SpO2 sensor & NIRP work on AUTO mode for 30 minutes interval); Charge time: <8 hours (2.5Ah)
Display Size: 12.1"; Type: Color TFT LCD; Resolution: 1280x800 pixels
Data storage Alarm event: 3000 groups and associated waveform; Trend: 1800h, minimum resolution is 10min 180h, minimum resolution is 1min 6h, minimum resolution is 5s; ARR event: 3000 groups and associated waveform; NIBP: 2400 groups; Holographic waveform: 72 hours
Size & Weight Dimension: 198mm X 320mm X 262mm; Weight: < 4kg
Interfacing & I/O devices Keyboard & Mouse: Support; Barcode Scanner: Support 1D barcode (USB connector); Wired network: 1 standard RJ45 interfaces; Wifi (option): Protocol: IEEE802.11a/b/g/n; Wifi frequency: Dual Band: 2.4G/5G; USB socket: 2 sockets; Video output: 1 VGA (option)
ECG Lead: 3-lead: I, I, II; 5-lead: I, II, III, aVR, aVL, aVF, V-; 6-lead: I, II, III, aVR, aVL, aVF, Va, Vb; Auto: identify leads automatically; Indication of lead-off: Every electrode Support ST, QT and ARR functions; Bandwidth (-3dB): Diagnostic mode: 0.05-150Hz; Monitor mode: 0.5-40Hz; Operation mode: 1-25Hz; ST mode: 0.05-40Hz; Signal quality display: Expression way: numerical display and waveform color; HR measurement range: 10-400 bpm; HR resolution: 1 bpm; HR accuracy: ±1% or ±1 bpm, whichever is greater
RESP Measurement parameter: Respiration Rate and respiration waveform; Source: RA-LA, RA-LL (default); Measurement range: 0-150 rpm; Resolution: 1 rpm; Accuracy: ±2 rpm or ±2%, whichever is greater.; Respiration Apnea Alarm: Fixed high priority alarm
BLT NIBP Measurement parameters: SYS, DIA, MAP,PR; Mode of operation: Manual, Auto, STAT, Sequence; Measurement range of cuff pressure: 0-300 mmHg; Initial inflation pressure:: Big animal: 120-280mmHg, default 160mmHg; Small animal: 60-280mmHg, default 160mmHg; Technique: Automatic Oscillometry; Dynamic pressure measurement range: SYS 30-270 mmHg (4.0-36.0 kPa), DIA 10-220 mmHg (1.3-29.3 kPa), MEAN 20-235 mmHg (2.7-31.3 kPa); Dynamic Pressure Measurement Error of Simulator: +8 mmHg (±1.1kPa); Static pressure accuracy: ±3 mmHg (±0.4kPa); Pressure resolution: 1 mmHg or 0.1kPa; PR Measurement range: 40 - 240 bpm; PR accuracy: 13bpm or ±3%, whichever is greater
Recorder Type: Thermal dot arrayPaper width: 50 mm +1mm; Recording speed: 12.5 mm/s, 25 mm/s, 50 mm/s; Recording waveform: Maximum 3 tracks
BLT Sp02 Measuring range: 0-100%; Sensitivity: High, Medium, Low; Accuracy: At 70-100%, ±2%, At 0~69%, unspecified; PR measurement range: 25 bpm -400 bpm; PR resolution: 1 bpm; PR accuracy: ± 3bpm (non-motion conditions); Pl measurement range: At least 0.05-20.00%; Pl resolution: 0.01%; Pl accuracy: ±0.1% or ±10% of reading, whichever is greater
TEMP Parameter: T1, T2,TD; Measurement site: Surface and coelom; Measuring range: 0.0-50.0°C (32°F-122°F); Resolution: 0.1°C or 0.1°F; Accuracy of circuit: ±0.1°C (±0.2°F) (without sensor)
CO2 Measurement parameter: EtCO2, FICO2, a CO2 waveform and awRR; Measurement method: Mainstream, Sidestream/Microflow; Unit: mmHg, kPa and %; EtCO2/FiCO2 measurement range: 0%~19.7% (0mmHg~ 150mmHg); EtCO2/FICO2 measurement accuracy: ± (0.43% + 8% of reading); EtCO2/FiCO2 display resolution: 0.1% or 1mmHg; awRR measurement range: 0~150 bpm; awRR measurement accuracy: ±1 bpm
IBP Static pressure measurement:: Measurement range: -6.7kPa~ + 48.0kPa (-50mmHg ~ + 360mmHg); Resolution: 1mmHg; Accuracy: ±0.3kPa (±2mmHg) or ±2%, whichever is greater (without sensor);; Dynamic pressure measurement:: Measurement range: -6.7kPa~+ 48.0kPa (-50mmHg ~ + 360mmHg); Accuracy: ±0.3kPa (+2mmHg) or ±2%, whichever is greater (without sensor); IBP zero range: -200mmHg - +200mmHg; Measuring range: -50-300 mmHg; Resolution : 1 mmHg; PR measurement range: 30 bpm-300 bpm; PR resolution: 1 bpm; PR accuracy: ±1% or ±1bpm whichever is greater
No resources available.
Weight 69156723416 kg
Dimensions 6923787706 × 6923557705 cm