| Weight | 69156723416 kg |
|---|---|
| Dimensions | 6923787706 × 6923557705 cm |
Portable Ultrasound, Ultrasonography, Veterinary
Login to purchase
SIUI Ultrasound V9 Lite – 15.6″ Monitor
SKU: VUV9L
V9 Lite delivers accurate, efficient imaging with a user-friendly keyboard and workflow for seamless operation.
• 15.6-inch adjustable monitor
• Maximum 4 probe connectors
• Digital power indicator
• Elegant keyboard layout
• Compatible with the height-adjustable trolley
• Quick ID – One-touch ID creation
• Real-time Worksheet Display – Quick view of results
• Flexible Measurement – Remove any individual measurement results
• Customized Report Template – Adapts to diverse usage habits
• Personalized Annotation & Body Mark – Suitable for different animals
• Self-defined Hotkey Function – Quick access of frequent-use functions
| Weight | Gross weight: 13kg(2 probes), 16.5kg(4 probes), Net weight: 7.2kg (Including 1 Battery) |
|---|---|
| Dimension | Gross dimension(mm) 630*330*510(2 probes), 630*420*510(4 probes), Net dimension(mm) 380*107*361, 430*150*390(with probe holder) |
| POWER | Battery = Rated Voltage: DC 11.1V, Charging Voltage: DC 12.6V, Rated Capacity: 7500mAh, 83.25Wh Adapter = Input: AC 100-240V, 2.5A, 50 Hz/60Hz, Output: DC 15V, 10A, Rated Power: 120VA |
| Memory Capacity | Film Length = 2D playback: 1~10000 frames, M, PW, DVR record, Image Format: Raw data(sfm)/BMP/JPG/ DCM/TIFF, Cine Format: Raw data(cin) /AVI/MP4/ DCM, Reedit the movie playback area, 2B/4B movie playback simultaneously, Store forward or backward |
| Connectivity | Video output: HDMI/VGA (Extendable to S-video/ Video/ print control port with video converter), Network port, 4 USB 3.0 ports, ECG port, Adapter port, Foot switch port |
| Standard Features | Frequency: Fundamental Frequency, THI (Tissue Harmonic imaging), MFI(Inversion THI), Fusion Frequency: Pen/Gen/Res, Speckle reduction: Nanoview, Nanopure, X-Beam: Compound Imaging, Series customization: Examination customization, Measurement customization, Annotation customization, Bodymark customization, Report template customization, Quick ID, Q-Preset, Trapezoidal/Extend imaging, Duplex/Triplex, Auto Flow, M/Color M/AMM, Panoscope, Auto Volume, CFM/PDI/DPDI/VS Flow, PW/HPRF, View Lock, Needle Enhancement, TDI, CW, Semi-auto EF, S-View, S-Station, Post processing, Sono Air, Account management, Smarchive, Historical Archive Query, Spectrum measurement: Auto Trace, Semi Auto Trace, Manual, Reverse Import, Custom Zoom, Raw Data Analysis, Auto-Fit: Automatic Optimization |
| Standard Accessories | Video Cable: HDMI Cable, S-video Cable. Power Cable, Printer Control Cable, Operation Manual, Recovery System USB, HDMI Video Converter, Power Adapter, Dust-proof Cover, Wireless Adapter, Probe Holder |
| Optional Accessories | Printer: Video printer, Laser or inkjet printer. Biopsy Guide: Convex probe, Linear probe. Trolley: CR-50. Probe Switcher: TQ-B016(Extends 1 socket to 4 sockets:Metal shell). Trolley case, VGA Video Converter, ECG Cable |
| Display Mode | B: B, 2B, 4B. M: M, B+M, B+M+CFM, B+TDI+M, AMM. B+Color: B+CFM, B+PDI, B+DPDI, B+VS Flow, Split B/CFM. B+Spectrum: B+PW, B+CW, HPRF. B+Color+Spectrum: B+CFM+PW, B+PDI+PW, B+DPDI+PW, B+VS Flow+PW, B+CFM+CW. Extend Mode: Trapezoid/Ext (Convex probe), Panoscope. |
| M Mode | MG(M Gain), Sweep speed, Gray Map, Chroma, Display layout, AMM |
| Appearance | Monitor: 15.6" high resolution color monitor, Angle Adjustment, Lean back 30°, Visual Angle, L&R 85°/U&D 85°, Control panel: Backlit keyboard, 8 TGC, Battery = Working Time: About 50 mins, Two Active Probe Connectors (Upgrade to 4 before delivery), Solid State Disk: 1T |
| Optional Features | DICOM 3.0 (Basic), DICOM 3.0 (Advance), MyWorkflow, PV Imaging, Micro Flow, Strain Elastography, CHI(Contrast Harmonic Imaging), ECG, SmartEcho, Free Hand 3D |
| General Parameters | GPU+CPU, Windows 10, System language: English, Russian, Spanish, French, German, Italian. Input language: English. Broadband/Multi-Frequency Technology, Digital LGC & Digital TGC, Gray scale: 256. Dynamic Range: 30-245dB. Max. Frame Rate display depth: Based on probe. Zoom: HD Zoom, Full-View Zoom, Full Screen. Focus: Continuous dynamic focus, 1-8 selectable transmit focus, SF(Small Focus). 8-step TGC slide pots |
| 2D Mode | BG(B Gain), Depth, Frequency, X-Beam, ENH(Edge Enhancement), Smooth, Nanoview, Nanopure, Persistence, Chroma, Gray Map, Power, B steer (Linear probe), B rotation, TSI, Line density, Inversion, Dual View/ Quad View. |
| CFM/PDI/DPDI Mode | CG(C Gain), Scale(PRF), Frequency, Wall filter, C Priority, C Gate, Median Filter, Thred, Color Map, Smooth, Color persistence, Line density, Color enhancement, B MIX, MIX, Power, Baseline (CFM), Steer (Linear probe), Tag Range(CFM), Tag Position(CFM), Color Hidden, B/C split, VS Flow, Color U/D |
| PW/CW Mode | PWG(PW Gain), CWG(CW Gain), Frequency, Gray Map, Chroma, Scale(PRF), Duplex /Triplex(PW), Baseline, Steer (Linear probe, PW), Wall filter, Angle, SV(Sampling volume) (PW), Volume, Sweep Speed, Smooth, Power, Auto Trace, Display layout, Trace Type, Trace Correction, Trace Sensitivity |
| TDI Mode | Help to assess the directional and temporal phase of cardiac so as to display the movement state of myocardium and the movement speed of heart. TDG(TDI Gain), Frequency, B Mix, Persistence, Scale(PRF), ENH(Enhancement), Wall Filter, Baseline, U/D, MIX, TDI Map, Thred, Priority, Power, Gate, Smooth, Med Filter, Color Hidden, B/C split, Available on the phased-array probes, TDI+PW: TDI-PW is used to display the trajectory of the movement velocity change of the myocardial tissue. On the time axis, it can intuitively reflect the movement velocity change of the myocardium during the cardiac cycle. It can measure the velocity of myocardial movement, the time length of each phase of the cardiac cycle, and calculate cardiac indicators such as TEI. TDI+M: Provide both myocardium motion velocity and direction. |
| AMM | The M mode scanning line can be adjusted 360 degrees to meet the measurement requirements of different cardiac chamber structures, so that the accuracy and reliability of measurement results are not affected by intracardiac structure or position deviation. |
| Auto Fit | The system can reduce noise and artifacts purify tissue shading and edging improve contrast resolution and help early identification of tissue/structure lesion. Available on B/CFM/PW |
| Post Processing | Parameter or mode can be adjusted in the saved original data image or movie, it helps to better diagnose the lesion. Available on B/CFM/PW/M mode |
| Quick ID | Quickly create ID, no need to input patient information, suitable for emergency situations |
| Archive Data Protection | The system will automatically continue the last exam if it is ended abnormally, it helps to protect archive data |
| Historical File Query | After inputting the patient ID, the system will automatically search for the existence of previous files, so that doctors can consult and quickly understand the patient's situation |
| Reverse Import | General measurement results can be set as specialty measurement items and be used in related calculations |
| Independent Sound Control | Sound of the spectrum and the buttons on the touch screen and control panel can be controlled independently to meet the daily needs of different users |
| Measurement Cursor Zoom | During the measurement process, the enlarged image around the measurement cursor is displayed in the lower right corner of the screen, which is suitable for the measurement of small lesions and accurate positioning |
| Trapezoidal (Virtual Convex) | Available on linear transducers, Extended Angle: L/R 15° |
| Panoscope | Available on Linear/Convex/Phased array transducers |
| Needle Enhancement | based on the ultrasonic beam deflection and imaging fusion, needle enhancement is used to strengthen the view of biopsy needle. Cooperated with the custom biopsy guides with adjustable needle angle available, it implements an effective biopsy for tumor. |
| VS Flow | Basing on MircoFlow, VS-Flow significantly upgrades the sensitivity and resolution of blood flow which helps doctors to maximize the clinical application value |
| Auto IMT | Auto IMT greatly improve the accuracy of intima-media measurement, simultaneously measure the thickness of anterior and posterior intima-media, and improve the clinical efficiency |
| Strain Elastography | visualize the stiffness of tissues in real time by delivering an external compression on the tissues. Clarity Smooth, E Map, Persistence, Dynamic range, EG(E Gain), Dual live with E and B mode, Pressure pilot lamp, Pressure guide with motion curves, Available on the Linear/Vaginal probes |
| Calculation | Measurement package: General,Abdomen, Repro(Cat), Repro(Dog), Small Part,Cardiology, Cardiology(Cat), Cardilogy(dog). Expand the measurement menu automatically. Measurement Rule: Repeat, Next, Non. Measurement Across Modes: Measurement items in different modes are contained in the same measurement package. When the mode is activated, the corresponding measurement items are also activated. Measurement Result: Reverse Import, Delete any measurement item at will, Move location at will, Adjustable size and color |
| Smarchive | Display the number of images in each archive. Preview images and movies without entering archives. Archive Backup Function. Archive Transmission: Background transmission, Multi path simultaneous transmission, Task manager to view the transfer progress. |
| Worksheet | Measurement results are placed in the front, which can be viewed without the need to enter the worksheet Specialty worksheet for easy viewing and comparing the measurement results of various exam types Worksheet interface supports modifying patient information |
No resources available.